# Jeanoko FV 200Hz10V Frequency-to-Voltage Converter Module, 0–200 Hz to 0–10 V

Convert 0–200 Hz digital pulses to 0–10 V analogue output for PLC and frequency-converter interfaces, with a calibratable mapping.

- [Original product page](https://www.ofertitastop.com/ca/product/jeanoko-fv-200hz10v-frequency-to-voltage)
- [View offer](https://www.ofertitastop.com/ca/visit/jeanoko-fv-200hz10v-frequency-to-voltage)
- Market: CA
- Language: en-CA
- Currency: CAD
- Product updated: 2026-10-26T03:45:07.807Z
- Brand: Jeanoko
- MPN: Jeanoko8mogb5r6zu
- SKU: ofertitastop-ca-33627
- Category: Electronics > Components > Converters
- Source store: amazon CA
- Active deal: Yes
- Price: 15.67 CAD
- Previous price: 19.59 CAD
- Discount: 20%
- Rating: 4.5 / 5
- Reviews: 3

Prices and deal status are the latest recorded data, not a guarantee of availability. Confirm the price and availability with the store.

## Description

Connect a digital pulse signal to an analogue voltage input when linking control equipment such as a PLC and a frequency converter. The Jeanoko FV 200Hz10V module converts frequencies from 0–200 Hz into a 0–10 V analogue signal.

Its stated conversion points are 20 Hz to 1 V, 100 Hz to 5 V and 200 Hz to 10 V. That defined relationship makes it easier to match a frequency signal to equipment that uses a voltage input.

Need a straightforward way to bridge those two signal formats? The module is designed for that specific interface task, including use with motion control cards.

## Key points

This single-channel module translates digital frequency input into analogue voltage output across the 0–200 Hz and 0–10 V ranges. The signal input accepts pulse levels of 5 V, 12 V or 24 V directly, without an added resistor. Its input is isolated, helping keep the signal interface separate from the rest of the setup.

The conversion relationship is provided at three reference points: 20 Hz produces 1 V, 100 Hz produces 5 V, and 200 Hz produces 10 V. A multi-turn potentiometer on the board is used to calibrate the frequency-to-voltage correspondence. The module is preset to a relationship at shipment, so calibration is available when it is needed rather than being part of routine setup.

## Usage tips

Plan the power supply and signal wiring around the input level you will use. The module’s supply range is 12–30 VDC, with 15–24 VDC recommended. For a 12 V pulse level, the supply must be at least 15 VDC, when using a 24 V input level, use a 24 VDC supply. If connecting a PLC, the module supports NPN type and requires a ground wire.

For encoder applications, keep the encoder rotating at a steady speed for more than 0.5 seconds. The stated response time is approximately 0.3–0.5 seconds, a practical consideration when setting up the control signal. Use the board’s potentiometer for calibration only when adjustment is required.

## Everyday use

In a PLC-to-frequency-converter interface, the module provides a way to turn a frequency signal into a voltage signal for the connected equipment. The same conversion can be used to match an interface between a motion control card and a frequency converter. Rather than choosing separate interface hardware for each signal format, this module focuses on the specific digital-frequency-to-analogue-voltage conversion.

For example, a control setup using a 100 Hz signal can use the stated 5 V reference point when matching the output to the receiving equipment. The three listed conversion points give a useful starting reference for planning the signal relationship, while the onboard potentiometer provides a means of calibration where needed.

## Practical questions

**What output corresponds to the input frequency?** The listed reference points are 20 Hz to 1 V, 100 Hz to 5 V and 200 Hz to 10 V. The board’s multi-turn potentiometer is used to calibrate that relationship.

**Which pulse levels can the input accept?** It accepts 5 V, 12 V and 24 V pulse levels directly, without an added resistor. For a 12 V pulse level, use a supply of at least 15 VDC, a 24 V input level calls for a 24 VDC supply.

**Can it be used with a PLC?** Yes. It is intended for PLC and frequency-converter interface work, supports NPN-type PLCs and requires a ground wire for that setup.

## Buying verdict

For a control system that needs a 0–200 Hz digital frequency signal converted to a 0–10 V analogue output, the Jeanoko module brings the conversion and calibration point together in one interface component. Its defined voltage mapping and support for PLC and motion-control connections make it a practical fit for frequency-to-voltage signal matching.

## Images

![Jeanoko FV 200Hz10V Frequency-to-Voltage Converter Module, 0–200 Hz to 0–10 V — 1](https://www.ofertitastop.com/i/neCpzwko9dYptssfJ1d6vF8NTAa7gigowZT1-iu0oWRFrEpHvAdujxp-y2U_PSCazVTYX_MMOUi7WGFZ1CRlSWX199ddfhQnxXJEmBsn88uEBkiWMfvP_Q.jpg)

![Jeanoko FV 200Hz10V Frequency-to-Voltage Converter Module, 0–200 Hz to 0–10 V — 2](https://www.ofertitastop.com/i/S4MWTZ5R29ICVXcXCqwkWCKyLT46guI6ma8wMHNBoT_WVlnATy0Vk7VDCcvpgI_7blzADP0hNpucq0YLuQF1zFeJ0FhqTX9lGT3ZdJUeXErisOk1iL1TIQ.jpg)

![Jeanoko FV 200Hz10V Frequency-to-Voltage Converter Module, 0–200 Hz to 0–10 V — 3](https://www.ofertitastop.com/i/jgO_WaFxZ1HJ6ukAoBTtbkh9DhaRKfL76lC6KcdgnaXHYPYJo1iSUm6yOVd-datR1idLzXULNLmroVIwoV7xDkV6bDZkP8jvOFDIVTmReAPOsGJ_ZyuE2g.jpg)

![Jeanoko FV 200Hz10V Frequency-to-Voltage Converter Module, 0–200 Hz to 0–10 V — 4](https://www.ofertitastop.com/i/OVtDyXGsCSaBbAv9ybmi2g4w7u2vrqd9Zi-RsovMxbTcG9TVobxu0ncmohpuIVJ9QzDhm-iNjna5fbDwj3HMtADwlHaoXxKXBIDBL5hKg73ETLW_7tFYDg.jpg)

![Jeanoko FV 200Hz10V Frequency-to-Voltage Converter Module, 0–200 Hz to 0–10 V — 5](https://www.ofertitastop.com/i/yk-xa3kl_oeqOZVoAw7kRL9d5s57Kci1FKwq1qMenwuu_DdauvG6BfOn9TyUwUTc_xMOvooyiKMfsOeOzQobDHmKCooUO1xr_nJ5Gh3RdBlwEq0VS4pB1g.jpg)